Actions and loads · Wind actions

Wind roughness factor

  • Type: Definition
  • Version 1

Terrain roughness factor depending on height z and roughness length z0.

cr=kr⋅ln⁡(zz0)\displaystyle c_{r} = k_{r} \cdot \ln\left(\frac{z}{z_{0}}\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

zcr

Formula and quantities

SymbolNameUnitNote
kr\displaystyle k_{r}Terrain factor–
z\displaystyle zHeight above groundm
z0\displaystyle z_{0}Roughness lengthm
cr\displaystyle c_{r}Roughness factor–Result

Worked example

kr\displaystyle k_{r} = 0.19 · z\displaystyle z = 10 m · z0\displaystyle z_{0} = 0.05 m

cr\displaystyle c_{r} = 1.00668 · Source: hand calculation: 0.19 · ln(200)

Scope and standard

Eurocode 1 (EN 1991-1-4:2005) Section 4.3.2 Eq. (4.4).

Result
cr\displaystyle c_{r} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
cr\displaystyle c_{r} = 1.00668= 0.19 · ln((10 m) / (0.05 m))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Wind actions.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.