Privacy settings

We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000012 · Skill

EN 1990EN 1991-1-1EN 1993-1-1

Design a two-span continuous steel beam to Eurocode 3

Enter the spans, the cross-section, the steel grade, the characteristic loads, and the lateral restraint of the top flange. Mia determines the internal forces with pattern loading, checks bending, shear, lateral-torsional buckling, and deflection to EN 1993-1-1, and shows each step with its clause.

Mia

Mia guides you step by stepShe guides you through the inputs and explains the results.

Worked example

IPE 300 · S235 · 6.00 + 6.00 m

All checks fulfilled
System
Two-span continuous beam, fork supports at A, B, and C
Spans
L1 = L2 = 6.00 m
Section
IPE 300 · S235
Loads
gk = 5.0 kN/m + self-weight · qk = 10.0 kN/m per span
Stability
Loads on the top flange · shear panel S = 1.0 · 10^7 kN (practically rigid)
Code
EN 1993-1-1, German National Annex · L/250

Design of a two-span steel beam to EN 1993-1-1. Continuous beam over two spans, L1 = L2 = 6.0 m, fork supports at all three supports. IPE 300, S235. Characteristic loads per span: gk = 5.0 kN/m, qk = 10.0 kN/m; add the self-weight (78.5 kN/m³). Loads act on the top flange. Top flange restrained by trapezoidal sheeting (shear panel, S = 1.0 · 10^7 kN). German National Annex. Deflection limit L/250.

Key results

Support moment MB
−99.5 kNm
Span moment M1 = M2
71.9 kNm
Shear force VEd at B
83.5 kN
Elastic critical factor αcr
4.61
Deflection w
9.3 mm ≤ 24.0 mm (η = 0.39)
Governing utilization
η = 0.76 (lateral-torsional buckling at support B)

Values of the calculation core and the EN 1993-1-1 steps of this skill for the stated inputs; they agree with an RFEM 6 Steel Design model of the same beam within 0.1 %. Combination 6.10 with γG = 1.35, γQ = 1.50, γM0 = 1.00, γM1 = 1.10.

  • — Self-weight A · γ = 0.42 kN/m (calculated) added to gk on both spans.
  • — Timoshenko beam with bending and shear deformation.
  • — The shear panel stiffness S = 1.0 · 10^7 kN is practically rigid; enter the value of the actual sheeting.
  • — With the recommended values (CEN, γM1 = 1.00) the governing utilization is η = 0.69.

Required inputs

  • Code: EN 1993-1-1 with the recommended values (CEN) or the National Annex of Germany, Austria, or the Czech Republic
  • Static system: spans L1 and L2 with fork supports at A, B, and C
  • Cross-section (I, H, or hollow section) and steel grade S235, S275, or S355
  • Characteristic permanent load gk and variable load qk per span, and whether the self-weight is added
  • Optional variable point loads Qk (up to two) and one partial line load qk,part, each with its span and position
  • Lateral restraint of the top flange, with the shear panel stiffness S
  • Deflection limit

What you receive

  • Governing check and utilization
  • Support moment MB, span moments, shear force, and support reactions
  • Section class, bending, shear, and their interaction
  • Elastic critical factor αcr, critical moment Mcr, and reduction factor χLT
  • Deflection against the limit
  • Assumptions, calculated quantities, and clause references
Reviewed calculation example

Start from an input template

These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.

Prepare your calculation
Dlubal CALC
Two-span steel beam | code, system, and loads
Structural calculation to standard

System sketch

L1 = 6L2 = 6gk,1 = 5qk,1 = 10gk,2 = 5qk,2 = 10

All required fields completed

Inputs completeReady to calculate

What this skill checks

Internal forces with pattern loading

16 ULS combinations and 4 characteristic SLS combinations per EN 1990 with the variable load per span. Support moment, span moments, shear force, support reactions, and deflection include shear deformation.

Cross-section resistance

Section class from the c/t ratios per EN 1993-1-1 Table 5.2, then bending, shear, and their interaction per 6.2 with section properties from the Dlubal cross-section library.

Lateral-torsional buckling of the whole beam

Elastic critical factor α_cr of the two-span member with the loads on the top flange and an optional shear panel there, then χ_LT per 6.3.2 for the governing combination.

Self-weight and National Annex

The self-weight A · γ with γ = 78.5 kN/m³ is added on request and reported as calculated. Partial factors follow the recommended values (CEN) or the National Annex of Germany, Austria, or the Czech Republic.

Ready for your first check?

Start with the example and adapt it to your structural system.

New calculation