Application conditions first
Building height, floor span, imposed load, support depth, wall thickness and clear height are checked against Table NA.2 before any load is asked; a violated condition is named with its value and limit.
Privacy settings
We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000080 · Skill
EN 1990EN 1996-1-1EN 1996-3Describe the wall, the floor above it, the masonry unit and mortar, and the vertical loads. Mia first checks the application conditions of DIN EN 1996-3/NA, then verifies the vertical load capacity at the wall head, mid-height and foot and names the governing point.
Mia guides you step by stepShe guides you through the inputs and explains the results.
Verify with the simplified method of DIN EN 1996-3/NA: single-leaf exterior wall of calcium silicate solid units KS 12 with NM IIa, t = 175 mm, long wall (1.00 m strip), two-sided support, standard overlap, RC floor fully supported (a = 175 mm), end support of a one-way intermediate floor with span 6.00 m, no centring strip, clear height 2.70 m, building height 18.6 m, qk = 3.25 kN/m² incl. partitions, characteristic loads at the wall head without self-weight NGk = 116.8 kN/m and NQk = 33.6 kN/m, unit weight 18 kN/m³.
fd = 0.85 · 6.0 / 1.5 = 3.40 N/mm²; ρ₂ = 0.75, hef = 2.025 m; NEd = 1.35 · 116.8 + 1.5 · 33.6 = 208.1 kN/m at the head plus the self-weight. The values match exercise 1.2 of Hochschule Karlsruhe (rounded there to 357/417/357 kN/m).
These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.
Building height, floor span, imposed load, support depth, wall thickness and clear height are checked against Table NA.2 before any load is asked; a violated condition is named with its value and limit.
f_k from Tables NA.D.1 to NA.D.10 for clay, calcium silicate, AAC, lightweight and normal concrete units with normal, thin-bed or lightweight mortar, or the value of an approval.
Φ₁ for end supports, roof slabs, two-way slabs and centring strips to DIN EN 1996-3/NA:2019-12 with the factor a/t, Φ₂ at mid-height with the effective height of two-, three- or four-sided walls.
The wall self-weight is added at mid-height and foot when the loads act at the wall head; walls and piers with A < 0.1 m² get the reduction factor 0.8 on f_d.
For exterior walls that are end supports of floors, the minimum load of 4.2.1.2 is checked when w_k and the permanent load at the wall head are given.
Normative basis
Basis of structural design. Framework for reliability and design situations.
Frequently asked questions
When all application conditions of DIN EN 1996-3/NA, 4.2.1.1 and Table NA.2 are met, among them a building height of at most 20 m, a floor span of at most 6.0 m (or a centring strip), qk ≤ 5.0 kN/m², a sufficient support depth and a clear height within the limit of the wall type and thickness. Mia checks every condition with your values first.
Both decide the application conditions and the reduction factor Φ₁ for the floor rotation at the wall head and foot. Mia never assumes them, also not a = t.
Yes. For products with a general building approval (abZ/aBG) the tables of Annex NA.D do not apply; enter fk and, if the approval gives another value, γM.
Characteristic values are always combined as NEd = 1.35 · NGk + 1.5 · NQk. A design value NEd can be entered instead in the chat.
Mia names the violated condition and refers to the refined method of DIN EN 1996-1-1/NA or to a structural analysis in RFEM.
Start with the example and adapt it to your structural system.
New calculation