Recommended values or German NA
EN 1992-1-1:2004+AC:2010 with the recommended values or with DIN EN 1992-1-1/NA, including the National Annex rules for the strut angle, the minimum reinforcement, and the load arrangement.
Privacy settings
We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000156 · Skill
EN 1990:2002+A1:2005, 6.4.3.2, Eq. (6.10), Table A1.2(B)EN 1992-1-1:2004+AC:2010, 5.1.3, 6.1, 6.2, 7.4.2, 9.2.1.1, 9.2.2DIN EN 1992-1-1/NA:2013-04+A1:2015-12, NCI to 5.1.3, NDP to 6.2.2, 6.2.3, 9.2.1.1, 9.2.2, NCI to 7.4.2(2)Enter the National Annex, the spans and supports, the section, the concrete and steel strengths, and the permanent and imposed loads per span. Mia computes the exact envelope over every imposed-load pattern, designs bending and shear at each critical section, checks the span/depth ratio, and reports the governing utilization with the clause named.
Mia guides you step by stepShe guides you through the inputs and explains the results.
Design a reinforced concrete continuous beam over three spans of 6 m to EN 1992-1-1:2004+AC:2010 with the recommended values: b/h = 30/60 cm, d = 55 cm, C30/37, B500, permanent load G = 20 kN/m plus self-weight, imposed load Q = 15 kN/m.
Values from the calculation code of the skill for the stated inputs, confirmed by RFEM. Combination 6.10 with 1.35 G and, per EN 1990 Table A1.2(B), 1.00 G, each with 1.5 Q patterned.
These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.
EN 1992-1-1:2004+AC:2010 with the recommended values or with DIN EN 1992-1-1/NA, including the National Annex rules for the strut angle, the minimum reinforcement, and the load arrangement.
The direct stiffness method evaluates every one of the 2^n imposed-load patterns for 3 to 20 spans with pin, fixed, or spring supports and an end overhang, with 1.35 G and 1.00 G to EN 1990 Table A1.2(B).
Required and minimum tension reinforcement to sections 6.1 and 9.2.1.1, the compression zone limit, and shear at d from the support face to section 6.2.3 with the strut angle and the minimum link ratio.
Deflection is screened with the span/depth ratio of section 7.4.2 per span, with the factor K for end and interior spans.
Normative basis
The checks follow these standards. Nationally determined parameters come from the National Annex selected in the form.
Edition used: EN 1992-1-1:2004 + AC:2010
| Country | National Annex | Factors | Source |
|---|---|---|---|
| DE | DIN EN 1992-1-1/NA:2013-04 + DIN EN 1992-1-1/NA/A1:2015-12Current | γC = 1.50γS = 1.15αcc = 0.85 | DIN Media |
Status checked on
Frequently asked questions
EN 1992-1-1:2004+AC:2010 with the recommended values or with the German National Annex DIN EN 1992-1-1/NA:2013-04 + NA/A1:2015-12. EN 1992-1-1:2023 is refused.
Published examples from Zilch/Zehetmaier and the JRC worked examples are recomputed by an automated test, and the envelopes of several systems are compared with RFEM.
EN 1990 Table A1.2(B) allows a favorable permanent load of 1.00 G. The skill checks 1.35 G and 1.00 G on all spans, each with the imposed load patterned, and never mixes both factors in one arrangement.
No. The design uses the elastic envelope with negative moments at the support centerline, which is conservative.
Start with the example and adapt it to your structural system.
New calculation