Résistance de calcul en compression axiale d'un poteau en béton armé en situation d'incendie avec section de béton réduite selon EN 1992-1-2 Annexe B.1 : NRdfi = Acfi · fcdfi + As · fsdfi.

NRd,fi=Ac,fi⋅fcd,fi+As⋅fsd,fi\displaystyle N_{\mathrm{Rd},fi} = A_{\mathrm{c},fi} \cdot f_{cd,fi} + A_{s} \cdot f_{sd,fi}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

AsNRdfi

Formula and quantities

SymbolNameUnitNote
Acfi\displaystyle A_{cfi}Aire efficace réduite de la section en bétonmm²
fcdfi\displaystyle f_{cdfi}Résistance de calcul en compression du béton en situation d'incendieN/m²
As\displaystyle A_{s}Aire totale des armatures longitudinalesmm²
fsdfi\displaystyle f_{sdfi}Limite d'élasticité de calcul des armatures en situation d'incendieN/m²
NRdfi\displaystyle N_{Rdfi}Résistance axiale de calcul en situation d'incendiekNResult

Exemple d’application

Acfi\displaystyle A_{cfi} = 100 000 mm² · fcdfi\displaystyle f_{cdfi} = 30 000 000 N/m² · As\displaystyle A_{s} = 2 400 mm² · fsdfi\displaystyle f_{sdfi} = 300 000 000 N/m²

NRdfi\displaystyle N_{Rdfi} = 3 720 kN

Standard and source

Result
NRdfi\displaystyle N_{Rdfi} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
NRdfi\displaystyle N_{Rdfi} = 3 720 kN= (100 000 mm²) · (30 000 000 N/m²) + (2 400 mm²) · (300 000 000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

La recherche commence dans Dimensionnement › Béton.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.