Dimensionnement · Bois

Résistance de calcul en flexion d'une poutre en bois au feu (EN 1995-1-2)

  • Type : Résistance
  • Version 1
  • revue le 21/11/2026

Moment résistant de calcul d'une poutre rectangulaire en bois en situation d'incendie par la méthode de la section réduite selon EN 1995-1-2 clause 4.2.2 : MRdfi = (bef · hef² / 6) · fmdfi.

MRd,fi=bef⋅hef26⋅fm,d,fi\displaystyle M_{\mathrm{Rd},fi} = \frac{b_{\mathrm{ef}} \cdot h_{\mathrm{ef}}^2}{6} \cdot f_{m,\mathrm{d},fi}
  • EN 1995-1-2:2004
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzbefhef

Formula and quantities

SymbolNameUnitNote
bef\displaystyle b_{\mathrm{ef}}Largeur résiduelle efficace de la section en boismm
hef\displaystyle h_{\mathrm{ef}}Hauteur résiduelle efficace de la section en boismm
fmdfi\displaystyle f_{mdfi}Résistance de calcul en flexion du bois en situation d'incendieN/m²
MRdfi\displaystyle M_{Rdfi}Moment résistant de calcul en situation d'incendiekNmResult

Exemple d’application

bef\displaystyle b_{\mathrm{ef}} = 102 mm · hef\displaystyle h_{\mathrm{ef}} = 351 mm · fmdfi\displaystyle f_{mdfi} = 27 600 000 N/m²

MRdfi\displaystyle M_{Rdfi} = 57,81 kNm

Standard and source

Standard
EN 1995-1-2:2004
Result
MRdfi\displaystyle M_{Rdfi} in kNm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
MRdfi\displaystyle M_{Rdfi} = 57,8059 kNm= ((102 mm) · (351 mm)² / 6) · (27 600 000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

La recherche commence dans Dimensionnement › Bois.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.