Dimensionnement · Bois

Résistance de calcul au cisaillement d'une poutre en bois au feu (EN 1995-1-2)

  • Type : Résistance
  • Version 1
  • revue le 21/11/2026

Résistance de calcul au cisaillement d'une poutre rectangulaire en bois en situation d'incendie avec section réduite selon EN 1995-1-2 clause 4.2.2 : VRdfi = (2 / 3) · bef · hef · fvdfi.

VRd,fi=23⋅bef⋅hef⋅fv,d,fi\displaystyle V_{\mathrm{Rd},fi} = \frac{2}{3} \cdot b_{\mathrm{ef}} \cdot h_{\mathrm{ef}} \cdot f_{v,\mathrm{d},fi}
  • EN 1995-1-2:2004
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzbefhef

Formula and quantities

SymbolNameUnitNote
bef\displaystyle b_{\mathrm{ef}}Largeur résiduelle efficace de la section en boismm
hef\displaystyle h_{\mathrm{ef}}Hauteur résiduelle efficace de la section en boismm
fvdfi\displaystyle f_{vdfi}Résistance de calcul au cisaillement du bois en situation d'incendieN/m²
VRdfi\displaystyle V_{Rdfi}Résistance de calcul au cisaillement en situation d'incendiekNResult

Exemple d’application

bef\displaystyle b_{\mathrm{ef}} = 102 mm · hef\displaystyle h_{\mathrm{ef}} = 351 mm · fvdfi\displaystyle f_{vdfi} = 4 025 000 N/m²

VRdfi\displaystyle V_{Rdfi} = 96,07 kN

Standard and source

Standard
EN 1995-1-2:2004
Result
VRdfi\displaystyle V_{Rdfi} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
VRdfi\displaystyle V_{Rdfi} = 96,0687 kN= (2 / 3) · (102 mm) · (351 mm) · (4 025 000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

La recherche commence dans Dimensionnement › Bois.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.