Progetto · Calcestruzzo

Snellezza limite di base per calcestruzzo debolmente armato (rho <= ρ0)

  • Tipo: Coefficiente
  • Versione 1
  • revisionata il 12/11/2026

Rapporto limite luce/altezza per elementi inflessi in c.a. senza calcolo diretto dell'inflessione secondo EN 1992-1-1 Eq. (7.16a).

(ld)=K⋅[11+1.5⋅fck⋅ρ0ρ+3.2⋅fck⋅(ρ0ρ−1)3/2]\displaystyle \left(\frac{l}{d}\right) = K \cdot \left[11 + 1.5 \cdot \sqrt{f_{ck}} \cdot \frac{\rho_{0}}{\rho} + 3.2 \cdot \sqrt{f_{ck}} \cdot \left(\frac{\rho_{0}}{\rho} - 1\right)^{3/2}\right]
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fck

Formula and quantities

SymbolNameUnitNote
K\displaystyle KFattore di schema strutturale (trave appoggiata 1,0; campata terminale 1,3; campata intermedia 1,5; sbalzo 0,4)1
fck\displaystyle f_{ck}Resistenza caratteristica a compressione cilindrica del calcestruzzoN/m²
ρ0\displaystyle \rho_{0}Rapporto di armatura di riferimento (10^-3 * sqrt(f_ck))1
ρ\displaystyle \rhoPercentuale richiesta di armatura tesa (A_s / (b * d))1
(l/d)\displaystyle (l/d)Rapporto fondamentale luce/altezza utile l/d1Result

Esempio svolto

K\displaystyle K = 1 1 · fck\displaystyle f_{ck} = 30.000.000 N/m² · ρ0\displaystyle \rho_{0} = 0,0054772 1 · ρ\displaystyle \rho = 0,0054772 1

(l/d)\displaystyle (l/d) = 19,2158 1 · Source: EN 1992-1-1:2004 Eq. (7.16a)

Scope and standard

Travi e solette in calcestruzzo armato con rho <= rho_0 secondo EN 1992-1-1.

Standard
EN 1992-1-1:2004, punto 7.4.2 (2), Eq. (7.16a)
Result
(l/d)\displaystyle (l/d) in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
(l/d)\displaystyle (l/d) = 19,2158 1= (1 1) · (11 + 1.5 · sqrt((30.000.000 N/m²) / 1 [MPa]) · ((0,0054772 1) / (0,0054772 1)) + 3.2 · sqrt((30.000.000 N/m²) / 1 [MPa]) · (max(0; (0,0054772 1) / (0,0054772 1) - 1))¹.5)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

La ricerca parte in Progetto › Calcestruzzo.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.