曲げ・せん断相関低減係数 ρ
鉛直せん断力が塑性せん断耐力の半分を超える場合(VEd > 0.5 · Vpl,Rd)の鋼ウェブ降伏強度低減係数:ρ = (2 · VEd / Vpl,Rd - 1)²。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 設計鉛直せん断力 | kN | ||
| 設計塑性せん断耐力 | kN | ||
| 鋼ウェブのせん断低減係数 | 1 | Result |
例題
= 540 kN · = 720 kN
= 0.25
Standard and source
- Standard
- EN 1994-1-1:2004
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.