Design · Composite

Moment-shear interaction reduction factor ρ

  • Type: Coefficient
  • Version 1
  • reviewed on 11/13/2026

Reduction factor for the yield strength of the steel web when vertical shear exceeds half the plastic shear resistance (VEd > 0.5 · Vpl,Rd): ρ = (2 · VEd / Vpl,Rd - 1)².

ρ=(2⋅VEd/Vpl,Rd−1)2\displaystyle \rho = (2 \cdot V_{\mathrm{Ed}} / V_{\mathrm{pl},\mathrm{Rd}} - 1)^2
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

VEd+VplRd-VplRd

Formula and quantities

SymbolNameUnitNote
VEd\displaystyle V_{\mathrm{Ed}}Design vertical shear forcekN
Vpl,Rd\displaystyle V_{\mathrm{pl},\mathrm{Rd}}Design plastic shear resistancekN
ρ\displaystyle \rhoShear reduction factor for steel web1Result

Worked example

VEd\displaystyle V_{\mathrm{Ed}} = 540 kN · Vpl,Rd\displaystyle V_{\mathrm{pl},\mathrm{Rd}} = 720 kN

ρ\displaystyle \rho = 0.25

Standard and source

Result
ρ\displaystyle \rho in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ρ\displaystyle \rho = 0.25 1= (2 · (540 kN) / (720 kN) - 1) ^ 2

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Composite.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.