모멘트-전단 상호작용 감소 계수 ρ

  • 유형: 계수
  • 버전 1
  • 2026. 11. 13.에 검토됨

수직 전단력이 소성 전단 저항의 절반을 초과할 때(VEd > 0.5 · Vpl,Rd) 강재 웨브 항복 강도 감소 계수: ρ = (2 · VEd / Vpl,Rd - 1)².

ρ=(2⋅VEd/Vpl,Rd−1)2\displaystyle \rho = (2 \cdot V_{\mathrm{Ed}} / V_{\mathrm{pl},\mathrm{Rd}} - 1)^2
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

VEd+VplRd-VplRd

Formula and quantities

SymbolNameUnitNote
VEd\displaystyle V_{\mathrm{Ed}}설계 수직 전단력kN
Vpl,Rd\displaystyle V_{\mathrm{pl},\mathrm{Rd}}설계 소성 전단 저항력kN
ρ\displaystyle \rho강재 웨브 전단 감소 계수1Result

예제

VEd\displaystyle V_{\mathrm{Ed}} = 540 kN · Vpl,Rd\displaystyle V_{\mathrm{pl},\mathrm{Rd}} = 720 kN

ρ\displaystyle \rho = 0.25

Standard and source

Result
ρ\displaystyle \rho in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ρ\displaystyle \rho = 0.25 1= (2 · (540 kN) / (720 kN) - 1) ^ 2