Tスタブ設計引張耐力 モード2 FT,2,Rd
EN 1993-1-8 表6.2に基づく、破壊モード2(ボルト破断とフランジ降伏)のTスタブ設計引張耐力:FT,2,Rd = (2 · Mpl,2,Rd + n · Ft,tot,Rd) / (m + n)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| モード2設計塑性曲げ耐力 | kNm | ||
| ボルトから外端までの距離 | mm | ||
| ボルト列全体の引張耐力 | kN | ||
| ボルトからウェブフィレットまでの距離 | mm | ||
| モード2設計引張耐力 | kN | Result |
例題
= 12 kNm · = 35 mm · = 300 kN · = 40 mm
= 460 kN
Standard and source
- Standard
- EN 1993-1-8:2005
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.