Design · Steel

T-stub design tension resistance Mode 2 FT,2,Rd

  • Type: Resistance
  • Version 1
  • reviewed on 11/10/2026

T-stub design tension resistance for failure Mode 2 (bolt failure with flange yielding) according to EN 1993-1-8 Table 6.2: FT,2,Rd = (2 · Mpl,2,Rd + n · Ft,tot,Rd) / (m + n).

FT,2,Rd=(2⋅Mpl,2,Rd+n⋅Ft,tot,Rd)/(m+n)\displaystyle F_{T,2,\mathrm{Rd}} = (2 \cdot M_{\mathrm{pl},2,\mathrm{Rd}} + n \cdot F_{t,tot,\mathrm{Rd}}) / (m + n)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FT2RdmnMpl2RdFttotRd

Formula and quantities

SymbolNameUnitNote
Mpl,2,Rd\displaystyle M_{\mathrm{pl},2,\mathrm{Rd}}Design plastic moment resistance Mode 2kNm
n\displaystyle nDistance from bolt to outer edgemm
Ft,tot,Rd\displaystyle F_{t,tot,\mathrm{Rd}}Total bolt row tension resistancekN
m\displaystyle mDistance from bolt to web filletmm
FT,2,Rd\displaystyle F_{T,2,\mathrm{Rd}}Mode 2 design tension resistancekNResult

Worked example

Mpl,2,Rd\displaystyle M_{\mathrm{pl},2,\mathrm{Rd}} = 12 kNm · n\displaystyle n = 35 mm · Ft,tot,Rd\displaystyle F_{t,tot,\mathrm{Rd}} = 300 kN · m\displaystyle m = 40 mm

FT,2,Rd\displaystyle F_{T,2,\mathrm{Rd}} = 460 kN

Standard and source

Result
FT,2,Rd\displaystyle F_{T,2,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
FT,2,Rd\displaystyle F_{T,2,\mathrm{Rd}} = 460 kN= (2 · (12 kNm) + (35 mm) · (300 kN)) / ((40 mm) + (35 mm))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Steel.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.