設計 · 鋼構造
ウェブせん断座屈細長比 λw (EN 1993-1-5)
EN 1993-1-5 第5.3(3)項によるせん断座屈に対するウェブの修正細長比パラメータ: λw = (hw / tw) / (37.4 · eps · √(kτ)).
- EN 1993-1-5:2006
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| ウェブ内法高さ | mm | ||
| ウェブ厚さ | mm | ||
| 鋼材パラメータ epsilon = sqrt(235 / f_y) | 1 | ||
| せん断座屈係数 | 1 | ||
| ウェブせん断座屈細長比 | 1 | Result |
例題
= 1,200 mm · = 10 mm · = 0.814 · = 7.12
= 1.47722
Standard and source
- Standard
- EN 1993-1-5:2006
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 鋼構造で開始されます。
Miaknows the formula catalog and asks for what is missing.