せん断剛性を考慮した組立柱の臨界座屈荷重

  • タイプ:特性値
  • バージョン1
  • 2026/11/15にレビュー済み

有限なせん断剛性 Sv を考慮した組立圧縮材の弾性臨界座屈荷重: Ncr = (π² · E · Ieff) / (L² · (1 + (π² · E · Ieff) / (L² · Sv))).

Ncr=π2⋅E⋅IeffL2⋅(1+π2⋅E⋅IeffL2⋅Sv)\displaystyle N_{\mathrm{cr}} = \frac{\pi^2 \cdot E \cdot I_{\mathrm{eff}}}{L^2 \cdot \left(1 + \frac{\pi^2 \cdot E \cdot I_{\mathrm{eff}}}{L^2 \cdot S_{v}}\right)}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NcrL

Formula and quantities

SymbolNameUnitNote
E\displaystyle Eヤング係数N/m²
Ieff\displaystyle I_{\mathrm{eff}}有効断面二次モーメントm⁴
L\displaystyle L座屈長さm
Sv\displaystyle S_{v}ラチスまたはタイプレートのせん断剛性N
Ncr\displaystyle N_{\mathrm{cr}}弾性臨界座屈荷重NResult

例題

E\displaystyle E = 210,000,000,000 N/m² · Ieff\displaystyle I_{\mathrm{eff}} = 0.0001 m⁴ · L\displaystyle L = 6 m · Sv\displaystyle S_{v} = 20,000,000 N

Ncr\displaystyle N_{\mathrm{cr}} = 4,475,520 N

Standard and source

Result
Ncr\displaystyle N_{\mathrm{cr}} in N

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Ncr\displaystyle N_{\mathrm{cr}} = 4,470,400 N= (pi² · (210,000,000,000 N/m²) · (0.0001 m⁴)) / ((6 m)² · (1 + (pi² · (210,000,000,000 N/m²) · (0.0001 m⁴)) / ((6 m)² · (20,000,000 N))))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は断面 › 組立断面で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.