断面 · 組立断面
せん断剛性を考慮した組立柱の臨界座屈荷重
有限なせん断剛性 Sv を考慮した組立圧縮材の弾性臨界座屈荷重: Ncr = (π² · E · Ieff) / (L² · (1 + (π² · E · Ieff) / (L² · Sv))).
- General formula, independent of standards
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| ヤング係数 | N/m² | ||
| 有効断面二次モーメント | m⁴ | ||
| 座屈長さ | m | ||
| ラチスまたはタイプレートのせん断剛性 | N | ||
| 弾性臨界座屈荷重 | N | Result |
例題
= 210,000,000,000 N/m² · = 0.0001 m⁴ · = 6 m · = 20,000,000 N
= 4,475,520 N
Standard and source
- Result
- in N
Reference to clause and equation, no standard text. The description is written in our own words.