μEd から求める相対圧縮域深さ ξ
普通強度コンクリートの矩形応力度分布釣合条件から導かれる相対中立軸深さ: ξ = 1.25 · (1 - √(1 - 2 · μEd))。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 無次元相対曲げモーメント | – | ||
| 相対圧縮域深さ | – | Result |
例題
= 0.117647
= 0.156907 · Source: 手計算
Scope and standard
圧縮鉄筋なし純曲げ(mu_Ed <= 0.371)かつ f_ck <= 50 MPa の矩形コンクリート断面。
- Standard
- EN 1992-1-1:2004、6.1項
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.