由 μEd 求得的相对受压区深度 ξ
普通强度混凝土矩形应力块平衡推导的相对中性轴深度 ξ = x / d:ξ = 1.25 · (1 - √(1 - 2 · μEd))。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 无量纲相对弯矩 | – | ||
| 相对受压区深度 | – | Result |
实例
= 0.117647
= 0.156907 · Source: 手算
Scope and standard
f_ck <= 50 MPa、无受压钢筋(mu_Ed <= 0.371)纯弯矩作用下的矩形混凝土截面。
- Standard
- EN 1992-1-1:2004,第6.1条
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.