Actions and loads · Accidental actions

Fire compartment opening factor O (EN 1991-1-2)

  • Type: Property
  • Version 1
  • reviewed on 11/21/2026

Opening factor O of a fire compartment for parametric temperature-time curves according to EN 1991-1-2 Annex A Eq. (A.4): O = (Av · √(heq / m)) / At.

O=Av⋅heqAt\displaystyle O = \frac{A_{v} \cdot \sqrt{h_{eq}}}{A_{t}}
  • EN 1991-1-2:2002
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

heq

Formula and quantities

SymbolNameUnitNote
Av\displaystyle A_{v}Total area of vertical openings on all wallsm²
heq\displaystyle h_{eq}Weighted average window heightm
At\displaystyle A_{t}Total area of enclosure (walls, ceiling, floor including openings)m²
O\displaystyle OOpening factor (in m^(1/2))1Result

Worked example

Av\displaystyle A_{v} = 12 m² · heq\displaystyle h_{eq} = 2 m · At\displaystyle A_{t} = 300 m²

O\displaystyle O = 0.05657 1

Standard and source

Standard
EN 1991-1-2:2002
Result
O\displaystyle O in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
O\displaystyle O = 0.0565685 1= ((12 m²) · sqrt((2 m) / [m])) / (300 m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Accidental actions.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.