ガラスの荷重継続時間係数 kmod (EN 16612)
EN 16612 第8.1.3項 式(1)によるフロートガラスに作用する荷重継続時間係数 kmod: kmod = 0.663 · (tL / 1 s)^(-1/16).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 等価載荷継続時間 | s | ||
| 載荷期間修正係数 | 1 | Result |
例題
= 5 s
= 0.599553
Standard and source
- Standard
- EN 16612:2019
- Result
- in 1