設計 · 組積造構造
組積造の特性圧縮強度(薄層モルタル)
目地厚 0.5 mm〜3 mm の薄層モルタル組積造の特性圧縮強度:fk = K · fb⁰.85。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 組積造の実験定数 | – | > 0 | |
| 組積ユニットの標準化平均圧縮強度 | N/mm² | > 0 | |
| 組積造の特性圧縮強度 | N/mm² | Result |
例題
= 0.8 · = 6 N/mm²
= 3.66873 N/mm² · Source: 手計算
Scope and standard
EN 1996-1-1 条項 3.6.1.2 に基づく薄層モルタル組積造。
- Standard
- EN 1996-1-1-2005-a1:2012、3.6.1.2項、式 (3.2)
- Result
- in N/mm²
Reference to clause and equation, no standard text. The description is written in our own words.