設計 · 組積造構造

組積造の特性せん断強度

  • タイプ:特性値
  • バージョン1
  • 2026/11/13にレビュー済み

縦目地充填組積造の特性せん断強度:fvk = min(fvk0 + 0.4 · σd, fvk,lim)。

fvk=min⁡(fvk0+0.4⋅σd, fvk,lim⁡)\displaystyle f_{vk} = \min\left(f_{vk0} + 0.4 \cdot \sigma_{\mathrm{d}},\, f_{vk,\lim}\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fvkσd

Formula and quantities

SymbolNameUnitNote
fvk0\displaystyle f_{vk0}初期特性せん断強度N/mm²fvk0\displaystyle f_{vk0} ≥ 0
σd\displaystyle σ_{\mathrm{d}}せん断面に垂直な設計圧縮応力N/mm²σd\displaystyle σ_{\mathrm{d}} ≥ 0
fvk,lim\displaystyle f_{vk,\mathrm{lim}}特性せん断強度の上限値N/mm²fvk,lim\displaystyle f_{vk,\mathrm{lim}} > 0
fvk\displaystyle f_{vk}組積造の特性せん断強度N/mm²Result

例題

上限値以下

fvk0\displaystyle f_{vk0} = 0.2 N/mm² · σd\displaystyle σ_{\mathrm{d}} = 0.8 N/mm² · fvk,lim\displaystyle f_{vk,\mathrm{lim}} = 1 N/mm²

fvk\displaystyle f_{vk} = 0.52 N/mm² · Source: 手計算

上限値で制限

fvk0\displaystyle f_{vk0} = 0.2 N/mm² · σd\displaystyle σ_{\mathrm{d}} = 2.5 N/mm² · fvk,lim\displaystyle f_{vk,\mathrm{lim}} = 1 N/mm²

fvk\displaystyle f_{vk} = 1 N/mm² · Source: 手計算

Scope and standard

EN 1996-1-1 条項 3.6.2 に基づく鉛直圧縮応力を伴うせん断下の組積造。

Standard
EN 1996-1-1-2005-a1:2012、3.6.2項、式 (3.5)
Result
fvk\displaystyle f_{vk} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fvk\displaystyle f_{vk} = 0.52 N/mm²= min((0.2 N/mm²) + 0.4 · (0.8 N/mm²); (1 N/mm²))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 組積造構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.