设计 · 砌体
受剪砌体墙受压区长度
忽略抗拉强度按线性应力分布计算的受压区长度:e <= l/6 时 lc = l;e > l/6 时 lc = 1.5 · (l - 2 · e)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 墙体总长度 | mm | > 0 | |
| 面内荷载偏心距 M_Ed / N_Ed | mm | ≥ 0 | |
| 墙体受压长度 | mm | Result |
Valid if
实例演算
未开裂截面 e = 300 mm <= 3000/6
= 3,000 mm · = 300 mm
= 3,000 mm · Source: 手算
开裂截面 l = 3000 mm, e = 800 mm
= 3,000 mm · = 800 mm
= 2,100 mm · Source: 手算
Scope and standard
EN 1996-1-1 第 6.2(2) 条(适用于 e < l / 2)。
- Standard
- EN 1996-1-1-2005-a1:2012,第6.2条
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
检索将在 设计 › 砌体 开始。
Miaknows the formula catalog and asks for what is missing.