構造解析 · 柱と安定性

相対板細長比

  • タイプ:特性値
  • バージョン1

板座屈に対する相対細長比:λ̄p = √(fy / σcr,p)(EN 1993-1-5による)。

λˉp=fyσcr,p\displaystyle \bar{\lambda}_{p} = \sqrt{\frac{f_{y}}{\sigma_{\mathrm{cr},p}}}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

λp

Formula and quantities

SymbolNameUnitNote
fy\displaystyle f_{y}降伏強度N/mm²
σcr,p\displaystyle \sigma_{\mathrm{cr},p}臨界板座屈応力度N/mm²
λˉp\displaystyle \bar{\lambda}_{p}相対板細長比–Result

例題

fy\displaystyle f_{y} = 235 N/mm² · σcr,p\displaystyle \sigma_{\mathrm{cr},p} = 75.92 N/mm²

λˉp\displaystyle \bar{\lambda}_{p} = 1.76 · Source: sqrt(235 / 75.92) = 1.76

Scope and standard

EN 1993-1-5による板座屈検定。

Result
λˉp\displaystyle \bar{\lambda}_{p} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
λˉp\displaystyle \bar{\lambda}_{p} = 1.75936= sqrt((235 N/mm²) / (75.92 N/mm²))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は構造解析 › 柱と安定性で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.