設計 · 鋼構造
ボルトの設計支圧耐力 Fb,Rd
ボルトの設計支圧耐力:Fb,Rd = k1 · αb · fu · d · t / γM2。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 荷重と直角方向の端距離係数 | – | ||
| 荷重方向の端距離係数 | – | ||
| 接合板の引張強度(最大値) | N/mm² | ||
| ボルト径 | m | ||
| 板厚 | m | ||
| 部分係数 | – | ||
| 設計支圧耐力 | kN | Result |
例題
= 2.5 · = 0.8 · = 360 N/mm² · = 0.02 m · = 0.01 m · = 1.25
= 115.2 kN · Source: EN 1993-1-8:2005 Tabelle 3.4
Scope and standard
EN 1993-1-8 表3.4に基づくボルトせん断接合。
- Standard
- EN 1993-1-8:2005、3.6.1項、式 表 3.4
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 鋼構造で開始されます。
Miaknows the formula catalog and asks for what is missing.