設計 · 鋼構造
ボルトの設計引張耐力 Ft,Rd
ボルトの設計引張耐力:Ft,Rd = k2 · fub · As / γM2。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| ボルト係数 | – | ||
| ボルトの引張強度(最大値) | N/mm² | ||
| ボルトの引張応力面積 | m² | ||
| 接合部の部分係数 | – | ||
| 設計引張耐力 | kN | Result |
例題
= 0.9 · = 800 N/mm² · = 0.000245 m² · = 1.25
= 141.12 kN · Source: EN 1993-1-8:2005 Tabelle 3.4
Scope and standard
EN 1993-1-8 表3.4による引張を受けるボルト接合部(標準ボルトの場合 k_2 = 0.9)。
- Standard
- EN 1993-1-8:2005、3.6.1項、式 表 3.4
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 鋼構造で開始されます。
Miaknows the formula catalog and asks for what is missing.