設計 · 鋼構造

勾配 m = 3 の許容疲労繰返し数 NR (EN 1993-1-9)

  • タイプ:特性値
  • バージョン1
  • 2026/11/24にレビュー済み

EN 1993-1-9 第7.1(1)項によるS-N曲線の m = 3 勾配域における垂直応力範囲に対する許容繰返し数 NR: NR = 2e6 · (ΔσC / Δσ)³.

NR=2⋅106⋅(ΔσCΔσ)3\displaystyle N_{R} = 2 \cdot 10^6 \cdot \left(\frac{\Delta\sigma_{\mathrm{C}}}{\Delta\sigma}\right)^3
  • EN 1993-1-9:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ΔσCΔσNR

Formula and quantities

SymbolNameUnitNote
ΔσC\displaystyle \Delta\sigma_{\mathrm{C}}200万回繰返しにおけるディテール等級基準疲労強度N/m²
Δσ\displaystyle \Delta\sigma作用垂直応力範囲N/m²
NR\displaystyle N_{R}許容繰返し数1Result

例題

ΔσC\displaystyle \Delta\sigma_{\mathrm{C}} = 80,000,000 N/m² · Δσ\displaystyle \Delta\sigma = 100,000,000 N/m²

NR\displaystyle N_{R} = 1,024,000

Standard and source

Standard
EN 1993-1-9:2005
Result
NR\displaystyle N_{R} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
NR\displaystyle N_{R} = 1,024,000 1= 2000000 · ((80,000,000 N/m²) / (100,000,000 N/m²))³

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 鋼構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.