設計 · 鋼構造

鋼材の限界温度 Θa,cr (EN 1993-1-2)

  • タイプ:特性値
  • バージョン1
  • 2026/11/21にレビュー済み

EN 1993-1-2 第4.2.4項 式(4.22)による応力比 μ0(>= 0.013)に応じた炭素鋼構造部材の限界温度: Θacr = 39.19 · ln(1 / (0.9674 · μ0³.833) - 1) + 482.

Θa,cr=39.19⋅ln⁡ ⁣(10.9674⋅μ03.833−1)+482\displaystyle \Theta_{a,\mathrm{cr}} = 39.19 \cdot \ln\!\left(\frac{1}{0.9674 \cdot \mu_{0}^{3.833}} - 1\right) + 482
  • EN 1993-1-2:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

μ0

Formula and quantities

SymbolNameUnitNote
μ0\displaystyle \mu_{0}時刻 t = 0 における応力比(0.013〜0.99)1
Θacr\displaystyle \Theta_{acr}鋼材の限界温度(°C)1Result

例題

μ0\displaystyle \mu_{0} = 0.5 1

Θacr\displaystyle \Theta_{acr} = 584.99 1

Standard and source

Standard
EN 1993-1-2:2005
Result
Θacr\displaystyle \Theta_{acr} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Θacr\displaystyle \Theta_{acr} = 584.665 1= 39.19 · ln(1 / (0.9674 · (0.5 1)³.833) - 1) + 482

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 鋼構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.