設計 · 鋼構造
無被覆鋼部材の断面係数 Am/V (EN 1993-1-2)
EN 1993-1-2 第4.2.5.1項による火災にさらされる無被覆鋼部材の断面係数 Am/V: Sf = Am / V.
- EN 1993-1-2:2005
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 単位長さあたりの加熱表面積(加熱周長) | m | ||
| 単位長さあたりの体積(断面積) | m² | ||
| 断面係数 Am/V | m⁻¹ | Result |
例題
= 1.16 m · = 0.00538 m²
= 215.61 m⁻¹
Standard and source
- Standard
- EN 1993-1-2:2005
- Result
- in m⁻¹
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 鋼構造で開始されます。
Miaknows the formula catalog and asks for what is missing.