设计 · 钢

无保护钢构件截面系数 Am/V (EN 1993-1-2)

  • 类型:属性
  • 版本1
  • 2026/11/21已审核

根据 EN 1993-1-2 第 4.2.5.1 条受火无保护钢构件的截面系数 Am/V:Sf = Am / V。

AmV=AmV\displaystyle \frac{A_{m}}{V} = \frac{A_{m}}{V}
  • EN 1993-1-2:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
Am\displaystyle A_{m}单位长度受火表面积(受火周长)m
V\displaystyle V单位长度体积(截面面积)m²
Sf\displaystyle S_{f}截面系数 Am/Vm⁻¹Result

实例

Am\displaystyle A_{m} = 1.16 m · V\displaystyle V = 0.00538 m²

Sf\displaystyle S_{f} = 215.61 m⁻¹

Standard and source

Standard
EN 1993-1-2:2005
Result
Sf\displaystyle S_{f} in m⁻¹

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Sf\displaystyle S_{f} = 215.613 m⁻¹= (1.16 m) / (0.00538 m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 设计 › 钢 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.