EN 1995-1-1 表7.2に基づく許容限界比(例:L/300)に対する即時たわみの検証:η = winst / (L / limitratio)。

η=winst/(L/limitratio)\displaystyle \eta = w_{inst} / (L / limit_{ratio})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
winst\displaystyle w_{inst}実際の即時たわみmm
L\displaystyle L梁スパンmm
limitratio\displaystyle limit_{ratio}たわみ分母(例:L/300の場合は300)1
η\displaystyle \etaたわみ利用率1Result

例題

winst\displaystyle w_{inst} = 16 mm · L\displaystyle L = 6,000 mm · limitratio\displaystyle limit_{ratio} = 300

η\displaystyle \eta = 0.8

Standard and source

Result
η\displaystyle \eta in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
η\displaystyle \eta = 0.8 1= (16 mm) / ((6,000 mm) / (300 1))