作用・荷重 · 風荷重

MWFRS 設計用風圧力 (ASCE 7)

  • タイプ:作用
  • バージョン1
  • 2026/11/15にレビュー済み

ASCE/SEI 7-22 式27.3-1による閉鎖型または部分開放型剛構造建物の主風力抵抗系(MWFRS)の設計用風圧力: p = q · G · Cp - qi · GCpi.

p=q⋅G⋅Cp−qi⋅(GCpi)\displaystyle p = q \cdot G \cdot C_{p} - q_{i} \cdot (GC_{pi})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

qpCp

Formula and quantities

SymbolNameUnitNote
q\displaystyle q外圧速度圧N/m²
G\displaystyle Gガスト影響係数1
Cp\displaystyle C_{p}外部圧力係数1
qi\displaystyle q_{i}内圧速度圧N/m²
GCπ\displaystyle GC_\pi 内圧係数積1
p\displaystyle p設計用風圧力N/m²Result

例題

q\displaystyle q = 1,200 N/m² · G\displaystyle G = 0.85 1 · Cp\displaystyle C_{p} = 0.8 1 · qi\displaystyle q_{i} = 1,200 N/m² · GCπ\displaystyle GC_\pi = -0.18 1

p\displaystyle p = 1,032 N/m²

Standard and source

Standard
ASCE 7-22
Result
p\displaystyle p in kPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
p\displaystyle p = 1,032 N/m²= (1,200 N/m²) · (0.85 1) · (0.8 1) - (1,200 N/m²) · (-0.18 1)