Design wind pressure on the Main Wind Force Resisting System (MWFRS) of an enclosed or partially enclosed rigid building according to ASCE/SEI 7-22 Eq. 27.3-1: p = q · G · Cp - qi · GCpi.

p=q⋅G⋅Cp−qi⋅(GCpi)\displaystyle p = q \cdot G \cdot C_{p} - q_{i} \cdot (GC_{pi})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

qpCp

Formula and quantities

SymbolNameUnitNote
q\displaystyle qExternal velocity pressureN/m²
G\displaystyle GGust-effect factor1
Cp\displaystyle C_{p}External pressure coefficient1
qi\displaystyle q_{i}Internal velocity pressureN/m²
GCπ\displaystyle GC_\pi Internal pressure coefficient product1
p\displaystyle pDesign wind pressureN/m²Result

Worked example

q\displaystyle q = 1,200 N/m² · G\displaystyle G = 0.85 1 · Cp\displaystyle C_{p} = 0.8 1 · qi\displaystyle q_{i} = 1,200 N/m² · GCπ\displaystyle GC_\pi = -0.18 1

p\displaystyle p = 1,032 N/m²

Standard and source

Standard
ASCE 7-22
Result
p\displaystyle p in kPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
p\displaystyle p = 1,032 N/m²= (1,200 N/m²) · (0.85 1) · (0.8 1) - (1,200 N/m²) · (-0.18 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Wind actions.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.