하중 및 작용 · 지진 하중
지진 층간변위 활용비 (EN 1998-1)
EN 1998-1 제4.4.3.2절 식 (4.31)-(4.33)에 따른 빈발 지진작용 하 층간변위 손상제한 검토비: ηdr = (dr · ν) / (h · αlim).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 설계 층간변위 | mm | ||
| 짧은 재현주기에 대한 감소계수 (0.4 또는 0.5) | 1 | ||
| 층고 | mm | ||
| 허용 층간변위비 한계 (0.005, 0.0075 또는 0.010) | 1 | ||
| 층간변위 활용비 (<= 1.0) | 1 | Result |
예제
= 24 mm · = 0.5 1 · = 3,000 mm · = 0.005 1
= 0.8 1
Standard and source
- Standard
- EN 1998-1:2004
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
하중 및 작용 › 지진 하중에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.