하중 및 작용 · 지진 하중
층간변위 민감도 계수 (P-Δ)
2차 효과를 평가하기 위한 층간변위 민감도 계수: θ = (Ptot · dr) / (Vtot · h).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 해당 층 및 그 상부의 총 중력 하중 | kN | ≥ 0 | |
| 설계 층간변위 | mm | ≥ 0 | |
| 총 지진 층전단력 | kN | > 0 | |
| 층고 | mm | > 0 | |
| 층간변위 민감도계수 | – | Result |
예제
= 8,000 kN · = 15 mm · = 500 kN · = 3,000 mm
= 0.08 · Source: 수기 계산
Scope and standard
EN 1998-1, 제4.4.2.2항(theta <= 0.10이면 2차 효과 무시 가능).
- Standard
- EN 1998-1:2004, 4.4.2.2 절, 식 (4.28)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
하중 및 작용 › 지진 하중에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.