Actions and loads · Seismic actions

Seismic interstorey drift utilization ratio (EN 1998-1)

  • Type: Verification
  • Version 1
  • reviewed on 11/24/2026

Damage limitation verification ratio for interstorey drift under the frequent seismic action according to EN 1998-1 Clause 4.4.3.2 Eq. (4.31)-(4.33): ηdr = (dr · ν) / (h · αlim).

ηdr=dr⋅νh⋅αlim\displaystyle \eta_{dr} = \frac{d_{r} \cdot \nu}{h \cdot \alpha_{\mathrm{lim}}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

h

Formula and quantities

SymbolNameUnitNote
dr\displaystyle d_{r}Design interstorey driftmm
ν\displaystyle \nuReduction factor for lower return period (0.4 or 0.5)1
h\displaystyle hStorey heightmm
αlim\displaystyle \alpha_{\mathrm{lim}}Allowable drift ratio limit (0.005, 0.0075, or 0.010)1
ηdr\displaystyle \eta_{dr}Interstorey drift utilization ratio (<= 1.0)1Result

Worked example

dr\displaystyle d_{r} = 24 mm · ν\displaystyle \nu = 0.5 1 · h\displaystyle h = 3,000 mm · αlim\displaystyle \alpha_{\mathrm{lim}} = 0.005 1

ηdr\displaystyle \eta_{dr} = 0.8 1

Standard and source

Result
ηdr\displaystyle \eta_{dr} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ηdr\displaystyle \eta_{dr} = 0.8 1= ((24 mm) · (0.5 1)) / ((3,000 mm) · (0.005 1))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Seismic actions.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.