설계 · 복합

전단 연결도 η

  • 유형: 성질
  • 버전 1
  • 2026. 11. 13.에 검토됨

전단 연결도(연결재의 실제 종방향 전단력과 완전 전단 연결에 필요한 힘의 비): η = Nc / Ncf.

η=Nc/Ncf\displaystyle \eta = N_{\mathrm{c}} / N_{cf}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Ncη

Formula and quantities

SymbolNameUnitNote
Nc\displaystyle N_{\mathrm{c}}부분 연결 시 콘크리트 플랜지 압축력kN
Ncf\displaystyle N_{cf}완전 연결 시 콘크리트 플랜지 압축력kN
η\displaystyle \eta전단 연결도1Result

예제

Nc\displaystyle N_{\mathrm{c}} = 1,500 kN · Ncf\displaystyle N_{cf} = 2,500 kN

η\displaystyle \eta = 0.6

Standard and source

Result
η\displaystyle \eta in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
η\displaystyle \eta = 0.6 1= (1,500 kN) / (2,500 kN)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 복합에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.