設計 · 複合構造
せん断結合度 η
せん断結合度(シアコネクタの実軸方向せん断力と完全せん断結合に要する力の比):η = Nc / Ncf。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 部分せん断結合時のコンクリートフランジ圧縮力 | kN | ||
| 完全せん断結合時のコンクリートフランジ圧縮力 | kN | ||
| せん断結合度 | 1 | Result |
例題
= 1,500 kN · = 2,500 kN
= 0.6
Standard and source
- Standard
- EN 1994-1-1:2004
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 複合構造で開始されます。
Miaknows the formula catalog and asks for what is missing.