설계 · 유리
접합유리 전단전달계수 ω
EN 16612 부속서 D에 따른 2겹 접합유리판의 전단전달계수 ω (0 <= omega <= 1): ω = 1 / (1 + 9.6 · (E · Is · hint) / (Gint · hs² · a²)).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 유리의 탄성계수 | N/m² | ||
| 단위폭당 단면이차모멘트 매개변수 | m³ | ||
| 중간막 두께 | m | ||
| 중간막의 전단탄성계수 | N/m² | ||
| 유리판 중심면 간 거리 | m | ||
| 대표 경간 | m | ||
| 전단전달계수 | 1 | Result |
예제
= 70,000,000,000 N/m² · = 2e-8 m³ · = 0.00152 m · = 1,000,000 N/m² · = 0.00952 m · = 1.5 m
= 0.908941 1
Standard and source
- Standard
- EN 16612:2019
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
설계 › 유리에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.