Design · Glass
Laminated glass shear transfer coefficient ω
Shear transfer coefficient ω (0 <= omega <= 1) for a 2-ply laminated glass pane according to EN 16612 Annex D: ω = 1 / (1 + 9.6 · (E · Is · hint) / (Gint · hs² · a²)).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Young's modulus of glass | N/m² | ||
| Second moment of area parameter per unit width | m³ | ||
| Interlayer thickness | m | ||
| Shear modulus of interlayer | N/m² | ||
| Distance between pane mid-planes | m | ||
| Characteristic span | m | ||
| Shear transfer coefficient | 1 | Result |
Worked example
= 70,000,000,000 N/m² · = 2e-8 m³ · = 0.00152 m · = 1,000,000 N/m² · = 0.00952 m · = 1.5 m
= 0.908941 1
Standard and source
- Standard
- EN 16612:2019
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Glass.