I형 단면의 웹 슬렌더니스비 d/tw
국부 좌굴 분류를 위한 웹 깊이-두께비: d / tw = (h - 2 · tf) / tw.
- General formula, independent of standards
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 높이 | mm | > 0 | |
| 웨브 두께 | mm | > 0 | |
| 플랜지 두께 | mm | > 0 | |
| 웹 슬렌더니스비 | – | Result |
Valid if
예제
= 300 mm · = 8 mm · = 12 mm
= 34.5 · Source: 수기 계산: (300 - 24) / 8 = 34.5
Scope and standard
I형 단면, EN 1993-1-1 표 5.2.
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.