Web depth-to-thickness ratio for local buckling classification: d / tw = (h - 2 · tf) / tw.

dtw=h−2⋅tftw\displaystyle \frac{d}{t_{w}} = \frac{h - 2 \cdot t_{f}}{t_{w}}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzhtftw

Formula and quantities

SymbolNameUnitNote
h\displaystyle hDepthmmh\displaystyle h > 0
tw\displaystyle t_{w}Web thicknessmmtw\displaystyle t_{w} > 0
tf\displaystyle t_{f}Flange thicknessmmtf\displaystyle t_{f} > 0
d/tw\displaystyle d/t_{w}Web slenderness ratio–Result

Valid if2⋅tf<h\displaystyle 2 \cdot t_{f} < h

Worked example

h\displaystyle h = 300 mm · tw\displaystyle t_{w} = 8 mm · tf\displaystyle t_{f} = 12 mm

d/tw\displaystyle d/t_{w} = 34.5 · Source: hand calculation: (300 - 24) / 8 = 34.5

Scope and standard

I-section, EN 1993-1-1 Table 5.2.

Result
d/tw\displaystyle d/t_{w} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
d/tw\displaystyle d/t_{w} = 34.5= ((300 mm) - 2 · (12 mm)) / (8 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Cross-sections › Open thin-walled sections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.