설계 · 강재
강재 부재의 화재 시 설계인장저항 (EN 1993-1-2)
EN 1993-1-2 제4.2.3.1절 식 (4.4)에 따른 균일 온도 분포 강재 부재의 설계인장저항: NfitRd = (ky · A · fy) / γMfi.
- EN 1993-1-2:2005
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 온도 Theta에서의 강재 항복강도 감소계수 | 1 | ||
| 총 단면적 | mm² | ||
| 20°C에서의 강재 항복강도 | N/m² | ||
| 화재 시 강재 부분안전계수 (일반적으로 1.0) | 1 | ||
| 화재 시 설계인장저항 | kN | Result |
예제
= 0.78 1 · = 5,000 mm² · = 355,000,000 N/m² · = 1 1
= 1,384.5 kN
Standard and source
- Standard
- EN 1993-1-2:2005
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
설계 › 강재에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.