根据 EN 1993-1-2 第 4.2.3.1 条式 (4.4) 的均匀温度分布钢构件抗拉设计承载力:NfitRd = (ky · A · fy) / γMfi。

Nfi,Θ,Rd=ky,Θ⋅A⋅fyγM,fi\displaystyle N_{fi,\Theta,\mathrm{Rd}} = \frac{k_{y,\Theta} \cdot A \cdot f_{y}}{\gamma_{M,fi}}
  • EN 1993-1-2:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
ky\displaystyle k_{y}温度 Theta 下钢材屈服强度折减系数1
A\displaystyle A毛截面面积mm²
fy\displaystyle f_{y}20°C 时钢材屈服强度N/m²
γMfi\displaystyle \gamma_{Mfi}火灾下钢材分项系数(通常取 1.0)1
NfitRd\displaystyle N_{fitRd}火灾下抗拉设计承载力kNResult

实例

ky\displaystyle k_{y} = 0.78 1 · A\displaystyle A = 5,000 mm² · fy\displaystyle f_{y} = 355,000,000 N/m² · γMfi\displaystyle \gamma_{Mfi} = 1 1

NfitRd\displaystyle N_{fitRd} = 1,384.5 kN

Standard and source

Standard
EN 1993-1-2:2005
Result
NfitRd\displaystyle N_{fitRd} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
NfitRd\displaystyle N_{fitRd} = 1,384.5 kN= ((0.78 1) · (5,000 mm²) · (355,000,000 N/m²)) / (1 1)