Privacy settings

We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000156 · Skill

EN 1990:2002+A1:2005, 6.4.3.2, Eq. (6.10), Table A1.2(B)EN 1992-1-1:2004+AC:2010, 5.1.3, 6.1, 6.2, 7.4.2, 9.2.1.1, 9.2.2DIN EN 1992-1-1/NA:2013-04+A1:2015-12, NCI to 5.1.3, NDP to 6.2.2, 6.2.3, 9.2.1.1, 9.2.2, NCI to 7.4.2(2)

Design reinforced concrete continuous beams to Eurocode 2

Enter the National Annex, the spans and supports, the section, the concrete and steel strengths, and the permanent and imposed loads per span. Mia computes the exact envelope over every imposed-load pattern, designs bending and shear at each critical section, checks the span/depth ratio, and reports the governing utilization with the clause named.

Mia

Mia guides you step by stepShe guides you through the inputs and explains the results.

Worked example

3 x 6 m, 300/600 mm, C30/37, recommended values

All checks satisfied
3 x 6 m, 300/600 mm, C30/37, recommended values
Code
EN 1992-1-1:2004+AC:2010, recommended values
System
Three spans of 6.00 m, four pin supports
Section
b = 300 mm, h = 600 mm, d = 550 mm, C30/37, B500
Loads
G = 20 kN/m + self-weight 4.5 kN/m, Q = 15 kN/m patterned

Design a reinforced concrete continuous beam over three spans of 6 m to EN 1992-1-1:2004+AC:2010 with the recommended values: b/h = 30/60 cm, d = 55 cm, C30/37, B500, permanent load G = 20 kN/m plus self-weight, imposed load Q = 15 kN/m.

Key results

Interior support moment MEd
-213.6 kNm
End span moment MEd
176.7 kNm
Required top reinforcement at the interior supports
953 mm²
Governing utilization
0.39 (span/depth ratio, end span)

Values from the calculation code of the skill for the stated inputs, confirmed by RFEM. Combination 6.10 with 1.35 G and, per EN 1990 Table A1.2(B), 1.00 G, each with 1.5 Q patterned.

  • — Self-weight 25 kN/m³ added to G (4.5 kN/m)
  • — Negative moments at the support centerline, no moment redistribution
  • — No provided reinforcement given, so bending is reported as the required area
  • — Shear at d from the support face with cot θ = 2.5

Required inputs

  • National Annex: EN recommended values or DIN EN 1992-1-1/NA
  • Span lengths and support types from left to right
  • Section width b, total depth h, and effective depth d
  • Concrete strength fck and reinforcement yield strength fyk
  • Permanent load G and imposed load Q per span, and whether to add self-weight

What you receive

  • Governing check and utilization with the clause
  • Moment and shear envelope with the governing load arrangement
  • Required and minimum reinforcement at each span and support
  • Shear design at d from the support face and the required links
  • Span/depth ratio per span
  • Assumptions and limits of the calculation

Start from an input template

These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.

Prepare your calculation
Dlubal CALC
Continuous beam | EC 2 inputs
Structural calculation to standard

System sketch

All required fields completed

Inputs completeReady to calculate

What this skill checks

Recommended values or German NA

EN 1992-1-1:2004+AC:2010 with the recommended values or with DIN EN 1992-1-1/NA, including the National Annex rules for the strut angle, the minimum reinforcement, and the load arrangement.

Exact pattern loading

The direct stiffness method evaluates every one of the 2^n imposed-load patterns for 3 to 20 spans with pin, fixed, or spring supports and an end overhang, with 1.35 G and 1.00 G to EN 1990 Table A1.2(B).

Bending and shear at every critical section

Required and minimum tension reinforcement to sections 6.1 and 9.2.1.1, the compression zone limit, and shear at d from the support face to section 6.2.3 with the strut angle and the minimum link ratio.

Span/depth ratio

Deflection is screened with the span/depth ratio of section 7.4.2 per span, with the factor K for end and interior spans.

Ready for your first check?

Start with the example and adapt it to your structural system.

New calculation