Tasarım · Beton

Kolonlar için minimum boyuna donatı

  • Tür: Dayanım
  • Versiyon 1
  • 09.11.2026 tarihinde gözden geçirildi

EN 1992-1-1'e göre kolonlar için minimum boyuna donatı alanı: As,min = max(0.10 · (NEd / fyd); 0.002 · Ac).

As,min=max⁡(0.10⋅NEdfyd;  0.002⋅Ac)\displaystyle A_{s,\mathrm{min}} = \max\left(0.10 \cdot \frac{N_{\mathrm{Ed}}}{f_{yd}};\; 0.002 \cdot A_{\mathrm{c}}\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

As,minNEd

Formula and quantities

SymbolNameUnitNote
NEd\displaystyle N_{\mathrm{Ed}}Tasarım eksenel basınç kuvvetikN
fyd\displaystyle f_{yd}Donatı çeliğinin tasarım akma dayanımıN/mm²
Ac\displaystyle A_{\mathrm{c}}Brüt beton kesit alanım²
As,min\displaystyle A_{s,\mathrm{min}}Minimum boyuna kolon donatısı alanım²Result

Çözümlü örnek

NEd\displaystyle N_{\mathrm{Ed}} = 800 kN · fyd\displaystyle f_{yd} = 434,783 N/mm² · Ac\displaystyle A_{\mathrm{c}} = 0,09 m²

As,min\displaystyle A_{s,\mathrm{min}} = 0,000184 m² · Source: EN 1992-1-1:2004 Denk. (9.12N)

Scope and standard

EN 1992-1-1 Madde 9.5.2'ye göre eksenel basınç altındaki donatılı beton kolonlar.

Standard
EN 1992-1-1:2004, madde 9.5.2 (2), Denk. (9.12N)
Result
As,min\displaystyle A_{s,\mathrm{min}} in m²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
As,min\displaystyle A_{s,\mathrm{min}} = 0,000184 m²= max(0.10 · ((800 kN) / (434,783 N/mm²)); 0.002 · (0,09 m²))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

Arama Tasarım › Beton içinde başlıyor.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.