Design · Concrete
Minimum longitudinal reinforcement for columns
Minimum longitudinal reinforcement area for columns according to EN 1992-1-1: As,min = max(0.10 · (NEd / fyd); 0.002 · Ac).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Design axial compression force | kN | ||
| Design yield strength of reinforcing steel | N/mm² | ||
| Gross concrete cross-sectional area | m² | ||
| Minimum area of longitudinal column reinforcement | m² | Result |
Worked example
= 800 kN · = 434.783 N/mm² · = 0.09 m²
= 0.000184 m² · Source: EN 1992-1-1:2004 Eq. (9.12N)
Scope and standard
Reinforced concrete columns under axial compression according to EN 1992-1-1, clause 9.5.2.
- Standard
- EN 1992-1-1:2004, clause 9.5.2 (2), Eq. (9.12N)
- Result
- in m²
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.
Miaknows the formula catalog and asks for what is missing.