设计 · 混凝土

预应力传递恒定粘结应力 fbpt (EN 1992-1-1)

  • 类型:属性
  • 版本1
  • 2026/11/25已审核

根据 EN 1992-1-1 第 8.10.2.2(1) 条式 (8.15) 先张法预应力筋传递长度上的恒定粘结应力:fbpt = ηp1 · η1 · fctd,t。

fbpt=ηp1⋅η1⋅fctd,t\displaystyle f_{bpt} = \eta _{p1} \cdot \eta _{1} \cdot f_{ctd,t}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fbpt

Formula and quantities

SymbolNameUnitNote
ηp1\displaystyle \eta_{p1}预应力筋类型粘结系数(刻痕钢丝取 2.7,钢绞线取 3.2)1
η1\displaystyle \eta_{1}粘结条件系数(良好取 1.0,其他取 0.7)1
fctd,t\displaystyle f_{ctd,t}放张预应力时的混凝土设计抗拉强度N/m²
fbpt\displaystyle f_{bpt}恒定传递粘结应力N/m²Result

实例

ηp1\displaystyle \eta_{p1} = 3.2 · η1\displaystyle \eta_{1} = 1 · fctd,t\displaystyle f_{ctd,t} = 1,800,000 N/m²

fbpt\displaystyle f_{bpt} = 5,760,000 N/m²

Standard and source

Result
fbpt\displaystyle f_{bpt} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fbpt\displaystyle f_{bpt} = 5,760,000 N/m²= (3.2 1) · (1 1) · (1,800,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 设计 › 混凝土 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.