忽略抗拉强度按线性应力分布计算的受压区长度:e <= l/6 时 lc = l;e > l/6 时 lc = 1.5 · (l - 2 · e)。

lc={l,e≤l/61.5⋅(l−2e),e>l/6\displaystyle l_{\mathrm{c}} = \begin{cases} l, & e \le l/6 \\ 1.5 \cdot (l - 2e), & e > l/6 \end{cases}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzllc

Formula and quantities

SymbolNameUnitNote
l\displaystyle l墙体总长度mml\displaystyle l > 0
e\displaystyle e面内荷载偏心距 M_Ed / N_Edmme\displaystyle e ≥ 0
lc\displaystyle l_{\mathrm{c}}墙体受压长度mmResult

Valid if2⋅e<l\displaystyle 2 \cdot e < l

实例演算

未开裂截面 e = 300 mm <= 3000/6

l\displaystyle l = 3,000 mm · e\displaystyle e = 300 mm

lc\displaystyle l_{\mathrm{c}} = 3,000 mm · Source: 手算

开裂截面 l = 3000 mm, e = 800 mm

l\displaystyle l = 3,000 mm · e\displaystyle e = 800 mm

lc\displaystyle l_{\mathrm{c}} = 2,100 mm · Source: 手算

Scope and standard

EN 1996-1-1 第 6.2(2) 条(适用于 e < l / 2)。

Standard
EN 1996-1-1-2005-a1:2012,第6.2条
Result
lc\displaystyle l_{\mathrm{c}} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
lc\displaystyle l_{\mathrm{c}} = 3,000 mm= if((300 mm) <= (3,000 mm) / 6; (3,000 mm); 1.5 · ((3,000 mm) - 2 · (300 mm)))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 设计 › 砌体 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.