依据 EN 1993-1-8 6.2.5 公式 6.6,柱底板下混凝土节点设计承压强度:fjd = (2 / 3) · kj · fck / γc。

fjd=(2/3)⋅kj⋅fck/γc\displaystyle f_{jd} = (2 / 3) \cdot k_{j} \cdot f_{ck} / \gamma _{\mathrm{c}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fjdfckkj

Formula and quantities

SymbolNameUnitNote
kj\displaystyle k_{j}节点集中系数1
fck\displaystyle f_{ck}特征圆柱抗压强度N/m²
γc\displaystyle \gamma_{\mathrm{c}}混凝土分项安全系数1
fjd\displaystyle f_{jd}节点设计承压强度N/m²Result

实例

kj\displaystyle k_{j} = 1.5 · fck\displaystyle f_{ck} = 30,000,000 N/m² · γc\displaystyle \gamma_{\mathrm{c}} = 1.5

fjd\displaystyle f_{jd} = 20,000,000 N/m²

Standard and source

Result
fjd\displaystyle f_{jd} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fjd\displaystyle f_{jd} = 20,000,000 N/m²= (2 / 3) · (1.5 1) · (30,000,000 N/m²) / (1.5 1)