设计 · 钢
底板下节点设计承压强度 fjd
依据 EN 1993-1-8 6.2.5 公式 6.6,柱底板下混凝土节点设计承压强度:fjd = (2 / 3) · kj · fck / γc。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 节点集中系数 | 1 | ||
| 特征圆柱抗压强度 | N/m² | ||
| 混凝土分项安全系数 | 1 | ||
| 节点设计承压强度 | N/m² | Result |
实例
= 1.5 · = 30,000,000 N/m² · = 1.5
= 20,000,000 N/m²
Standard and source
- Standard
- EN 1993-1-8:2005
- Result
- in MPa
Reference to clause and equation, no standard text. The description is written in our own words.